Commercial Fire Detection System
Addressable Fire Detection System
Control Panel
Digital Addressable 1 Loop (256 devices)
Techincal data
* Power Supply: AC187-242V/50Hz, AC100~12V/60Hz
* Loop Voltage: DC15-28V
* Loop Current: ≤200mA
* Short Circuit Protection: ≤400mA
* Loop Capacity: 256~2048 devices
* Sounder Output: DC22~27.5V/1A
* Passive Output: DC30V/1A
* Programmable Output: DC30V/1A
* auxiliary(Auxiliary) Power Output: DC30V/2A
* Temperature: -10ºC ~ 50ºC
* Humidity: ≤95%RH(40±2ºC)
* Installation: Wall-mount
* Dimensions(Dimension): 480*355*120*mm
* Batteries: Two DC12V/7Ah
* Cable: 1.5mm² or above shield cable
Digital Addressable 2 Loops (512 devices)
Techincal data
* Power Supply: AC187-242V/50Hz, AC100~12V/60Hz
* Loop Voltage: DC15-28V
* Loop Current: ≤200mA
* Short Circuit Protection: ≤400mA
* Loop Capacity: 256~2048 devices
* Sounder Output: DC22~27.5V/1A
* Passive Output: DC30V/1A
* Programmable Output: DC30V/1A
* auxiliary(Auxiliary) Power Output: DC30V/2A
* Temperature: -10ºC ~ 50ºC
* Humidity: ≤95%RH(40±2ºC)
* Installation: Wall-mount
* Dimensions(Dimension): 480*355*120*mm
* Batteries: Two DC12V/7Ah
* Cable: 1.5mm² or above shield cable
Digital Addressable 3 Loops (768 devices)
Techincal data
* Power Supply: AC187-242V/50Hz, AC100~12V/60Hz
* Loop Voltage: DC15-28V
* Loop Current: ≤200mA
* Short Circuit Protection: ≤400mA
* Loop Capacity: 256~2048 devices
* Sounder Output: DC22~27.5V/1A
* Passive Output: DC30V/1A
* Programmable Output: DC30V/1A
* auxiliary(Auxiliary) Power Output: DC30V/2A
* Temperature: -10ºC ~ 50ºC
* Humidity: ≤95%RH(40±2ºC)
* Installation: Wall-mount
* Dimensions(Dimension): 480*355*120*mm
* Batteries: Two DC12V/7Ah
* Cable: 1.5mm² or above shield cable
Digital Addressable 4 Loops (1024 devices)
Techincal data
* Power Supply: AC187-242V/50Hz, AC100~12V/60Hz
* Loop Voltage: DC15-28V
* Loop Current: ≤200mA
* Short Circuit Protection: ≤400mA
* Loop Capacity: 256~2048 devices
* Sounder Output: DC22~27.5V/1A
* Passive Output: DC30V/1A
* Programmable Output: DC30V/1A
* auxiliary(Auxiliary) Power Output: DC30V/2A
* Temperature: -10ºC ~ 50ºC
* Humidity: ≤95%RH(40±2ºC)
* Installation: Wall-mount
* Dimensions(Dimension): 480*355*120*mm
* Batteries: Two DC12V/7Ah
* Cable: 1.5mm² or above shield cable
Intelligent Addressable 4 Loops (1024 devices)
Techincal data
* Power Supply: AC187-242V/50HZ
* Loop Voltage: DC15-28V
* Loop Current: 200mA
* Short-Circuit Protection: Max.400mA
* Loop Capacity: 256/512/768/1024 devices
* Active Output : DC24V/1A
* Sounder Circuit: DC24V/1A
* auxiliary(Auxiliary) Power: DC24V/4A
* Network: 64 panles(panels)
* Dimension: 460*620*120mm
* Installation: Wall-mount
Smoke Detectors
Digital Fire Alarm System Photoelectric Smoke Detector
Technical Data
* Operating Voltage: DC16V~28V
* Standby Current:≤0.5mA
* Alarm Current: ≤1.0mA
* Sensitivity: 4 levels
* Indicator: Flash as Standby, Illuminate as Alarm
* IP Rating: IP32
* Temperature: -10ºC~+55ºC
* Humidity ≤95%,non-condensing
* Material of Enclosure: ABS
* Dimension: D-100mm, H-43mm (without base)
* Weight: About 120g
* Base:VG-6617
Heat Detectors
Digital Fire Alarm System Heat/Temperature Detector
Technical Data
* Operating Voltage: DC16V~28V
* Standby Current:≤0.5mA
* Alarm Current: ≤1.0mA
* Classification: A1R or A2
* Indicator: Flash as Standby, Illuminate as Alarm
* IP Rating: IP32
* Temperature: -10ºC~+55ºC
* Humidity ≤95%,non-condensing
* Material of Enclosure: ABS
* Dimension: D-100mm, H-43mm (without base)
* Weight: About 120g
* Base:VG-6617
Bell / Sounder
Digital Sounder Beacon Strobe
Technical Data
* Operating Voltage: DC16V~28V
* Standby Current: ≤ 0.3mA
* Action Current: ≤8.0mA
* Alarm Tone: 16 types
* Alarm Volume: 4 levels
* Visual Indication: 0.2s light on; 0.8s light off
* IP Rating: IP21C
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH (40±2ºC)non-condensing
* Dimension: D-100mm, H-43mm (without base)
* Weight: About 120g
* Base: VG-6619
Call Point
Digital Fire Alarm System Manual Call Point
Technical Data
* Operating Voltage: DC16V ~28V
* Standby Current: ≤0.5mA
* Alarm Current: ≤1mA
* Indicator: Red. Illuminates in alarm
* Class: Type A, indoor use
* IP Rating: IP43
* Temperature: -10ºC~+55ºC
* Humidity: ≤95%, non-condensing
* Material of Enclosure: ABS
* Dimension: 88*88*58mm (with back box) 88*88*23mm (without back box)
* Weight: About 160g (with back box) About 107g (without back box)
Other Products
Digital Fire Alarm System Repeater
Technical Data
* Power Supply: DC24V
* Operating Voltage: DC15V-28V
* Operating Current: ≤60mA
* Standby Current: ≤0.7mA
* Standby Power: ≤1W
* Display: 100 alarmed address
* Temperature: 0ºC~45ºC
* Relative Humidity: ≤95%RH(40±2ºC)
* Addresse: 0# ~ 255#
* Installation: Wall-mount
* Dimension: 171*140*32mm
Digital Fire Alarm System Isolator Interface/Module
Technical Data
* Operating Voltage: DC18V-28V
* Standby current: ≤1mA
* Isolate condition: Loop voltage ≤7.5V
* Isolate current: ≤10mA
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH (40±2ºC)non-condensing
* Installation: Wall-mount
* IP rate: 32
* Dimension: 82*82*39mm (with base)
* Weight: 127.1g (with base)
* Base: VG-6618
Digital Fire Alarm System Input/Monitor Module/Interface
Technical Data
* Operating Voltage: DC16V-28V
* Standby current: ≤0.5mA
* Action current: ≤1.0mA
* Input: Passive contacts
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH (40±2ºC)non-condensing
* Installation: Wall-mount
* Dimension: 82*82*39mm (with base)
* Weight: 110.1g (with base)
* Base: VG-6618
Digital Fire Alarm System Programmer
Techincal data
* Working Voltage: DC9V
* Address: 0# ~ 255#
* Working Current: ≤10mA
* Standby Current: ≤10μA
* Digital Display:8-bit numbers or characters
* Power Supply Mode: 6F22 Carbon Battery
* Applicable Temperature: -10ºC~ +50ºC
* Outline Dimension: 152mm×56mm×24mm (body)
* Environment Humidity: ≤95%RH (40±2ºC) no condensation
* Accessory: MCP Adapter, Module Adapter, Clips
* Weight: 143g (without battery)
Digital Fire Alarm System Alert/Sounder Base
Technical Data
Operating Voltage | Loop voltage: 24V /Allowance range: 15V~28V (Vp-p) |
Standby Current | 0.2 mA |
Action current: | ≤ 3mA |
Total starting current at alarm state both for the detector and alert base ≤ 3.5mA (maximum 20 pieces triggered at exactly the same time) | |
Address | 1~254 |
Sound level | >75dB |
Tonal modification cycle | 0.6~1.5S |
Temperature | 10ºCºC~+55 |
Relative Humidity | ≤95%,non-condensing |
Shell material and color | ABS+PC, White |
Dimension | diameter of 102mm, height of 25.5mm |
Installation hole distance | 73mm |
Weight | 67g |
Conventional Fire Detection System
Control Panel
Conventional Fire Alarm Control Panel 6831/2 (2 zones)
Technical Data
* Power Supply: AC220V/50Hz or AC110V/60Hz
* Operating Voltage: DC15V~28V
* Standby Current: ≤6mA
* Action Current: 400mA
* Passive Output: DC24V/1A
* Sounder Circuit: DC18V~28V, 300mA&
* Auxiliary Power : DC18V~28V, 500mA
* Temperature: 0ºC~40ºC
* Humidity ≤95%,non-condensing
* Dimension: 430*330*105mm
* Installation: Wall-mount
* Batteries: Two DC12V/7Ah
* Cable: 1.5mm² or above shield cable
Conventional Fire Alarm Control Panel (4 zones)
Technical Data
* Power Supply: AC220V/50Hz or AC110V/60Hz
* Operating Voltage: DC15V~28V
* Standby Current: ≤6mA
* Action Current: 400mA
* Passive Output: DC24V/1A
* Sounder Circuit: DC18V~28V, 300mA
* Auxiliary Power : DC18V~28V, 500mA
* Temperature: 0ºC~40ºC
* Humidity ≤95%,non-condensing
* Dimension: 430*330*105mm
* Installation: Wall-mount
* Batteries: Two DC12V/7Ah
* Cable: 1.5mm² or above shield cable
Conventional Fire Alarm Control Panel (8 zones)
Technical Data
* Power Supply: AC220V/50Hz or AC110V/60Hz
* Operating Voltage: DC15V~28V
* Standby Current: ≤6mA
* Action Current: 400mA
* Passive Output: DC24V/1A
* Sounder Circuit: DC18V~28V, 300mA
* Auxiliary Power : DC18V~28V, 500mA
* Temperature: 0ºC~40ºC
* Humidity ≤95%,non-condensing
* Dimension: 430*330*105mm
* Installation: Wall-mount
* Batteries: Two DC12V/7Ah
* Cable: 1.5mm² or above shield cable
Conventional Fire Alarm Control Panel (16 zones)
Technical Data
* Power Supply: AC220V/50Hz or AC110V/60Hz
* Operating Voltage: DC15V~28V
* Standby Current: ≤6mA
* Action Current: 400mA
* Passive Output: DC24V/1A
* Sounder Circuit: DC18V~28V, 300mA
* Auxiliary Power : DC18V~28V, 500mA
* Temperature: 0ºC~40ºC
* Humidity ≤95%,non-condensing
* Dimension: 430*330*105mm
* Installation: Wall-mount
* Batteries: Two DC12V/7Ah
* Cable: 1.5mm² or above shield cable
Smoke Detectors
Conventional Fire Alarm System Photoelectric Smoke Detector
Technical Data
*Operating Voltage:DC9V~28V
* Standby Current:≤60μA
* Alarm Current:10mA≤I≤50mA
* Indicator: Flash as Standby, Illuminate as Alarm
* Remote Indicator Output: 10kΩ resistor required
* IP Rating: IP32
* Temperature: -10ºC~+55ºC
* Humidity ≤95%,non-condensing
* Material of Enclosure: ABS
* Dimension: D-100mm, H-43mm
* Weight: About 120g
Heat Detectors
Conventional Fire Alarm System Dual Heat/Temperature Detector
Technical Data
*Operating Voltage:DC9V~28V
* Standby Current:≤60μA
* Alarm Current:10mA≤I≤50mA
* Classification: A2R
* Indicator: Flash as Standby, Illuminate as Alarm
* Remote Indicator Output: 10kΩ resistor required
* IP Rating: IP32
* Temperature: -10ºC~+55ºC
* Humidity ≤95%,non-condensing
* Material of Enclosure: ABS
* Dimension: D-100mm, H-43mm
* Weight: About 120g
Bell / Sounder
Conventional Sounder Strobe Beacon
Technical Data
* Operating Voltage: DC20V~28V
* Action Current:≤35mA
* Alarm Tone: 16 types
* Flashing Frequency: 1.4×(1±20%)Hz
* IP Rating: IP21C
* Temperature: -10ºC~+50ºC
* Humidity: ≤95%, non condensing
* Material of Enclosure: ABS
* Dimension: 152*91*49.5mm
* Weight: About 210g
Conventional Alarm Bell 6 Inch 152mm
Technical Data
* Operating Voltage: DC24V
* Alarm Current:≤20mA
* Alarm Volume:≥95dB
* Temperature:0ºC~50ºC
* Humidity: ≤95%RH(40±2ºC)
* Dimension: Diameter 152mm
* Appearance Colour: Red
Call Point
Conventional Fire Alarm System Manual Call Point
Technical Data
* Operating Voltage: DC12V~28V
* Standby Current: ≤0.5mA
* Alarm Current: ≤20mA
* Class: Type A, indoor use
* IP Rating: IP43
* Temperature: -10ºC~+55ºC
* Humidity: ≤95%, non-condensing
* Material of Enclosure: ABS
* Dimension: 88*88*58mm (with back box)
88*88*23mm (without back box)
* Weight: About 160g (with back box)
About 107g (without back box)
Intelligent Fire Detection System
Control Panel
Intelligent Addressable 1 Loop (100 devices)
Techincal data
* Power Supply: AC180V-252V/50HZ
* Loop Voltage: DC15-28V
* Loop Current: 200mA
* Short-Circuit Protection: Max.400mA
* Loop Capacity: 40 or 100 devices
* Passive Output : DC30V/1A
* Sounder Circuit: DC24V/300mA
* Temperature: -10ºC ~ 50ºC
* Humidity: ≤95%RH(40±2ºC)
* Installation: Wall-mount
* Dimension: 320*240*68mm
Intelligent Addressable 1 Loop (256 devices)
Techincal data
* Power Supply: AC187-242V/50HZ
* Loop Voltage: DC15-28V
* Loop Current: 200mA
* Short-Circuit Protection: Max.400mA
* Loop Capacity: 256/512/768/1024 devices
* Active Output : DC24V/1A
* Sounder Circuit: DC24V/1A
* auxiliary(Auxiliary) Power: DC24V/4A
* Network: 64 panles(panels)
* Dimension: 460*620*120mm
* Installation: Wall-mount
Intelligent Addressable 2 Loops (512 devices)
Techincal data
* Power Supply: AC187-242V/50HZ
* Loop Voltage: DC15-28V
* Loop Current: 200mA
* Short-Circuit Protection: Max.400mA
* Loop Capacity: 256/512/768/1024 devices
* Active Output : DC24V/1A
* Sounder Circuit: DC24V/1A
* auxiliary(Auxiliary) Power: DC24V/4A
* Network: 64 panles(panels)
* Dimension: 460*620*120mm
* Installation: Wall-mount
Intelligent Addressable 3 Loops (768 devices)
Techincal data
* Power Supply: AC187-242V/50HZ
* Loop Voltage: DC15-28V
* Loop Current: 200mA
* Short-Circuit Protection: Max.400mA
* Loop Capacity: 256/512/768/1024 devices
* Active Output : DC24V/1A
* Sounder Circuit: DC24V/1A
* auxiliary(Auxiliary) Power: DC24V/4A
* Network: 64 panles(panels)
* Dimension: 460*620*120mm
* Installation: Wall-mount
Intelligent Addressable 4 Loops (1024 devices)
Techincal data
* Power Supply: AC187-242V/50HZ
* Loop Voltage: DC15-28V
* Loop Current: 200mA
* Short-Circuit Protection: Max.400mA
* Loop Capacity: 256/512/768/1024 devices
* Active Output : DC24V/1A
* Sounder Circuit: DC24V/1A
* auxiliary(Auxiliary) Power: DC24V/4A
* Network: 64 panles(panels)
* Dimension: 460*620*120mm
* Installation: Wall-mount
Smoke Detectors
Intelligent Addressable Fire Alarm System Photoelectric Smoke Detector
Technical Data
* Operating Voltage: DC15V-28V
* Standby Current: ≤0.5mA
* Alarm Current: ≤1.0mA
* Protection area: ≤80m²
* Installation Height: ≤12m * Transmit Distance: Max. 2000m
* Temperature: -10ºC~ +55ºC
* Humidity: ≤95%RH (40±2ºC)non-condensing
* Dimension: D-100mm, Height-56mm (include base)
* Weight: 83.8g
* Base: VG-6611A
Heat Detectors
Intelligent Addressable Fire Alarm System Heat/Temperature Detector
Technical Data
* Operating Voltage: DC15V-28V
* Standby Current: ≤0.5mA
* Alarm Current: ≤1.0mA
* Classification: A2
* Protection area: ≤30m²
* Installation Height: ≤8m
* Alarm Temperature: +54ºC~ +70ºC
* Transmit Distance: Max. 2000m
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH (40±2ºC)non-condensin
* Dimension: D-100mm, H-56mm (include base)
* Weight: 64.4g
Bell / Sounder
Intelligent Addressable Sounder Strobe Beacon
Technical Data
* Operating Voltage: DC15V~28V
* Standby Current: ≤ 0.5mA
* Action Current: ≤50mA
* Cycle: 2*(1±20%)
* Flash: 1Hz ~ 2Hz
* Sound: 80~95dB
* Transmit Distance: Max. 2000m
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH (40±2ºC)non-condensing
* Dimension: 152*91*50mm (with base)
* Weight: 203.9g (with base)
Call Point
Intelligent Addressable Fire Alarm System Manual Call Point
Technical Data
* Operating Voltage: DC15V-28V
* Standby Current: ≤0.4mA
* Action Current: ≤0.9mA
* Contact capacity: 30VDC/100mA,br/> * Transmit Distance: Max. 2000m
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH, non-condensing
* Dimension: 88*90*32mm
Other Products
Intelligent Addressable Fire Alarm System Dual Output/Control Module/Interface
Technical Data
* Operating Voltage: DC15V-28V
* Standby current: ≤1.0mA
* Action current: ≤1.5mA
* Input: Passive with EOL resistor 4.7k * Output: Active 1A/30VDC
* Transmit Distance: Max. 2000m
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH (40±2ºC)non-condensing
* Installation: Wall-mount
* Dimension:120*82*39mm (with base)
* Weight: 179.1g (with base)
Intelligent Addressable Fire Alarm System Input/Monitor Module/Interface
Technical Data
* Operating Voltage: DC15V-28V
* Standby current: ≤0.5mA
* Action current: ≤0.6mA
* Input: Passive with EOL resistor 4.7k * Transmit Distance: Max. 2000m
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH (40±2ºC)non-condensing
* Installation: Wall-mount
* Dimension: 82*82*39mm (with base)
* Weight: 110.1g (with base)
Intelligent Addressable Fire Alarm System Output/Control Module/Interface
Technical Data
* Operating Voltage: DC15V-28V
* Standby current: ≤0.5mA
* Action current: ≤0.6mA
* Input: Passive with EOL resistor 4.7k
* Output: Active 1A/30V or Passive
* Transmit Distance: Max. 2000m
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH (40±2ºC)non-condensing
* Installation: Wall-mount
* Dimension: 82*82*39mm (with base)
* Weight: 115.1g (with base)
Intelligent Addressable Fire Alarm System DC-AC Converter Module/Interface
Technical Data
* Operating Voltage: DC20V-30V
* Action current: ≤30mA
* Output: 5A, 250VAC/30VDC
* Temperature: -10ºC~ +50ºC
* Humidity: ≤95%RH (40±2ºC)non-condensing
* Installation: Wall-mount
* Dimensions: 82*82*39mm (with base)
* Weight: 127.1g (with base
Gas Extinguishing Detection System
Control Panel
Gas Extinguishing Panel (4 detection zones and 2 extinguishing zones)
Technical Data
* Power Supply: AC 187V~252V/50HZ
* Battery: two batteries, 2.3AH/12V
* Operating Voltage: 24-28VDC
* Extinguishing Zone: 2 zones
* Detection Zone: Four detection zones, connect with conventional detectors
* Detection Capacity: 15 detectors for each detection zone
* Action Voltage: 24-28VDC
* Max. Action Current: 2A
* Temperature: -10ºC~45ºC
* Humidity: ≤95%RH(40±2ºC)
* Installation: Wall-mount
* Dimension: 430*300*108mm
Gas Extinguishing Panel (2 extinguishing zones)
Technical Data
* Power Supply: 24V-28VDC
* Extinguishing Zone: 2 zones
* Cylinder Start Voltage: 24-28VDC
* Maximum Start Current: 2A
* Temperature: -10ºC~45ºC
* Humidity: ≤95%RH(40±2ºC)
* Installation: Wall-mount
* Dimension: 320*68*240mm
Start/Abort Button
Gas Extinguishing System Start/Abort Button
Techincal data
* Operating Voltage: DC24V-28V
* Standby Current: ≤0.4mA
* Action Current: ≤50mA
* Operating Temperature: -10ºC~+50ºC
* Relative Humidity: ≤95%RH(40±2ºC)
* Mounting: Wall-mounted
* Dimension: 100*160*45mm
Gas Extinguishing System Start/Abort Button
Techincal data
* Operating Voltage: DC22V-30V
* Standby Current: ≤0.4mA
* Contact Capacity: 24V/5A
* Operating Temperature: -10ºC~+50ºC
* Relative Humidity: ≤95%RH(40±2ºC)
* Mounting: Wall-mount or Flush-mount Dimension: 86*86*48mm
Gas Releasing Sign
Gas Extinguishing System Gas Releasing Sign
Techincal data
* Operating Voltage: 22V-28VDC
* Action Current: ≤25mA
* Flash Rate: flashing 45±5 times one minute
* Operating Temperature: 0ºC~50ºC
* Relative Humidity: ≤95%RH(40±2ºC)
* Mounting: Wall-mounted
* Dimension: 275*121*30mm